Targeted cooling

Directed airspeed is an effective airspeed. Our Cyclone fans have been specially designed to cool cows that are lying down in stalls, where air moved by other methods may not penetrate fully. Their deflectors generate uniform layers of air that blanket an area to keep animals cool and happy, by the bedding dry and insects at bay. They are the best choice of ventilation wherever cows are lying down, be it in stalls or in open areas.

Options

  • Available in sizes 36" (91.5cm), 55" (140cm), 72" (183cm), & 84" (214cm)
  • Save on electricity with our variable Speed options
  • Available in Belt Drive and Direct Drive versions
  • High Output and High-Efficiency models
  • Multiple mounting options and accessories
  • High-Pressure Fogging attachments for extra cooling power

Peak Performances

Cyclone fan 36”: 15,500 m³/h | 9,610 CFM

Cyclone fan 55”: 47,900 m³/h | 24,950 CFM

Cyclone fan 72”: 82,700 m³/h | 48,770 CFM

Cyclone fan 84”: 120,300 m³/h | 66,820 CFM

Performance

Imperial | Metric

Model Drive Ph Volt Hz kw Amps RPM Speed Watts N N/kW m³/h W/1000m³/h
36 DD 1 230 50 0.37 2.1 940 100% 430 29.9 69.6 14 660 29.3
36 DD 3 400 50 0.37 1.3 940 100% 401 30.8 76.6 14 890 27
55 BD 3 230/400 50 1.1 4.6/2.7 384 100% 1 220 101 82.9 41 000 29.7
55 DD* 3 360-460 50/60 1.1 2.1 600 90% 949 108 114 42 550 22.3
72 BD 3 230/400 50 2.2 7.9/4.6 350 100% 2 280 210 92.4 77 750 29.3
72 DD* 3 400 50 2.2 4.7 400 100% 2 372 247.2 104.8 84 262 28
84 BD 3 400 50 4 7.9 348 100% 3 627 319 87.9 110 740 32.8
84 DD* 3 400 50 3.0 6.6 400 100% 3 068 302.5 98.6 107 384 28.6
Model Drive Ph Volt Hz HP [kw] Amps RPM Speed Watts lbf lbf/kW CFM CFM/W
36 DD 1 230 60 1/2 [0.37] 3.1 860 100% 557 8.4 15 9 610 20.1
36 DD 3 460 60 1/2 [0.37] 1.3 855 100% 475 8.1 17 9 460 21.9
55 BD 3 230/460 60 1.5 [1.1] 4.6/2.3 384 100% 1 220 22.7 18.6 24 132 19.8
55 DD* 3 360-460 50/60 1.5 [1.1] 2.1 600 90% 938 24.1 25.7 24 950 26.4
72 BD 3 230/460 60 3 [2.2] 7.7/3.9 350 100% 2 357 48.3 20.5 46 180 20.1
72 DD* 3 460 60 3 [2.2] 3.3 400 100% 2 359 55.6 23.6 49 595 21
84 BD 3 460 60 5 [4.0] 6.6 348 100% 3 920 75.3 19.2 66 820 18
84 DD* 3 460 60 4 [3.0] 4.5 400 100% 3 068 68 22.16 63 204 20.6

*EC motor with integrated variable speed control using 0-10VDC and/or Modbus communication. Single phase version only available for the models with the 1.1kW motor.

All fans are tested in accordance with AMCA 230-15 standard

Other motor configurations available

Ask your representative about our various Direct Drive models

Cyclone Fan 36 Direct Drive
Cyclone Fan 55 Belt Drive
Cyclone Fan 55 Direct Drive
Cyclone Fan 72 Belt Drive
Cyclone Fan 72 Direct Drive
Cyclone Fan 84 Belt Drive
Cyclone Fan 84 Direct Drive

Warranty

3-year

Warranty

On the entire fan
(Not including belts and tighteners)

5-year

Warranty

On the blades

10-year

Warranty

On frame and housing